O1010 – S1630 – Bathurst CBD MYD Consulting Engineers

100% Complete

Project Description

Reuse existing Antennas, Combiners, MHA and feeder
* Leave G900 system as it is in all sectors
* Leave U900 system as it is in all sectors
* Leave L700 system as it is in all sectors
* Leave L2600 system as it is in all sectors
*Install one L1800 (RRU Model# 3971) per sector.
* RRU must be 4T4R (L1800)
* Re-route U2100 along with L1800 through HB combiners
* Install two CS commscope high band combiners per sector.
*Install Fiber cable trunk as per requirement.
* Keep the configurations of other technologies as is.
* RF Tails not to exceed 5m between RRU and Antenna.

* Plumbing diagram maybe different from actual on-site. Need to record all equipment and verify while on SDV.

Documents

No documents at this time.

Project Progress

100% Progress

100% Timing

Start Date

December 24, 2017

End Date

December 28, 2017

9/9

Complete Milestones

4/4

Complete Phases

14/14

Complete Tasks

Milestones

9 / 9 Completed

100%

  • 10% Cover sheet + G1 Completion of Cover sheet and G1.
  • 30% G2 + G3 + G4 Completion of G2 and G3.
  • 40% A1 + A2 Completion of A1.
  • 50% F1 Completion of F1.
  • 65% Designer QA QA of FC drawings by designer.
  • 75% Officer QA QA of FC drawings by QA officer.
  • 80% Final Amendment Final amendment of FC drawings.
  • 90% Preparation of HOP Preparation of Hand Over pack.
  • 100% Submit Completed Job :) Submit Hand Over Pack.

Phases

Expand Discussions | 4 / 4 Completed

FC drawings 1 Document 9 / 9 Tasks 0 Responses

100%
Description

Completion of whole FC drawings by designer.

9 of 9 completedTasks

  • Cover Sheet Bahar
  • G1 Bahar
  • G2 Bahar
  • G3 Bahar
  • G4 Bahar
  • A1 Bahar
  • A2 Bahar
  • F1 Bahar
  • Designer QA Bahar

of 1 Approved No Documents Documents

No documents attached to this phase.

Discussion 0 Responses

Leave a Reply

QA Project By QA Officer 1 Document 1 / 1 Tasks 1 Responses

100%
Description

QA FC drawings by QA officer.

1 of 1 completedTasks

  • QA completed Daryoosh Asadi

of 1 Approved No Documents Documents

No documents attached to this phase.

Discussion 1 Response

  1. January 8, 2018 at 4:15 am
    Daryoosh

    QA has been completed.

Leave a Reply

Final Amendment 1 Document 1 / 1 Tasks 0 Responses

100%
Description

Final amendment on QA officer markups.

1 of 1 completedTasks

  • Final markups amendment Bahar

of 1 Approved No Documents Documents

No documents attached to this phase.

Discussion 0 Responses

Leave a Reply

HOP pack 1 Document 3 / 3 Tasks 0 Responses

100%
Description

Preparation of HOP files.

3 of 3 completedTasks

  • SID Bahar
  • WHS Bahar
  • MYD Certificate Bahar

of 1 Approved No Documents Documents

No documents attached to this phase.

Discussion 0 Responses

Leave a Reply

Project Discussion 0 Responses to O1010 – S1630 – Bathurst CBD

Leave a Reply

Update Status

Document Status Updated

Notifications have been sent.

Loading

Add Document

Upload    Web Address